Welcome To E POWER TECHNOLOGIES

EP IG SERIES

1 Phase Input / 1 Phase Output

5 KVA - 20KVA

Application

IT INFRATRUCTURE

TELECOM

MEDICAL EQUIPMENT

DATA PROCESSING EQUIPMENT

MACHINE TOOLS & ROBOTICS

BANK & FINANANCE

FEATURES

Microprocessor based intelligent UPS system suitable for IT and Medical Equipment Load with unity power factor and a wide input voltage Window of 140-300 with an overall efficiency reaching 95%.

It requires minimum battery sizing (lesser no. of Batteries 8Nos- 20Nos).
The peak surge handling capacity of 300% for 3000msc.
True Inbuilt Isolation Transformer by design@ output.
IGBT based Rectifier & charger.
Control Designed to withstand all kinds of load.
Intelligent Battery Management to Prolong Battery Life Cycle.

High Input Power factor >0.99.
High Reliability Digital control.
N+1 hot standby option uptolOunits.
Wide Input Voltage Range.
Inbuilt Manual Bypass Switch.
Emergency Power off (EPO) Switch.

Technical Specification

MODEL EPIG2005 EPIG2010 EPIG2015 EP1G2020
Capacity 5KVA 10KVA 15KVA 20KVA
INPUT
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 140V~280V AC Load Dependent
Operating Frequency Range 50 Hz + 1% (Auto Sensing)
Power Factor >0.9
OUTPUT
Output Voltage/Power Factor 220V / 230V / 240V AC / £1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50Hz
Harmonic Distortion (THDv) <2% (Linear load), <5% (Non Liner Load)
Crest Factor 3:1
Efficiency Up to 94% Dual Conversion Mode, 99% ECO Mode
BATTERY
DC Voltage 96V/120V 180/192V 192v 192
Charge Current 10% of the Rated Battery AH
Typical Recharge Time 8 Hours (90% of full capacity)
SYSTEM FEATURES
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency
LED Indication Load Level, Battery Level, Line On, Battery On, Inverter On, By Pass, Fault & Reset Button
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability < 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : Oms, Inverter to Bypass : 4ms (Typical)
ENVIRONMENTAL
Temperature Operating: 0~40°C, Storage: -10°C ~ 55°C
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
PHYSICAL
Dimension WxDxH (mm) 12x22.5x21 12x22.5x21 12.5x22.5x25
Weight (Kg) 5Kg 35Kg 38Kg 40Kg 45Kg 50Kg 60Kg 70Kg 75Kg
STANDARDS
Quality 150 9000, 1SO 14001, OHSAS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232 Optional
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Technology Online Double conversion AC-DC-AC with high switching frequency VFI Inversion Technology