Welcome To E POWER TECHNOLOGIES
Welcome To E POWER TECHNOLOGIES
IT INFRATRUCTURE
TELECOM
MEDICAL EQUIPMENT
DATA PROCESSING EQUIPMENT
MACHINE TOOLS & ROBOTICS
BANK & FINANANCE
Microprocessor based intelligent UPS system suitable for IT and Medical Equipment Load with unity power factor and a wide input voltage Window of 140-300 with an overall efficiency reaching 95%.
True online Double Conversion Topology.
The peak surge handling capacity of 300% for 3000msc.
True Inbuilt Isolation Transformer by design@ output.
IGBT based Rectifier & charger.
Control Designed to withstand all kinds of load.
Intelligent Battery Management to Prolong Battery Life Cycle.
High Input Power factor >0.99.
High Reliability Digital control.
N+1 hot standby option up to 10units
Wide Input Voltage Range.
Inbuilt Manual Bypass Switch.
Emergency Power off (EPO) Switch.
MODEL | EPIG+3010 | EPIG+3015 | EPIG+3020 | EPIG+3030 | EPIG+3060 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 60KVA | |||||||
INPUT | ||||||||||||
Nominal Voltage | 380V/400V/415V/ SELECTABLE AC (3PH+N+PE, 5WIRE.), 220V / 230V / 240V AC | |||||||||||
Operating Voltage Range | 360V~470V AC Load Dependent | |||||||||||
Operating Frequency Range | 50 Hz + 1% (Auto Sensing) | |||||||||||
Power Factor | >0.9 | |||||||||||
OUTPUT | ||||||||||||
Output Voltage/Power Factor | 220V / 230V / 240V AC / ±1% / 0.9 Optional | |||||||||||
Output Frequency | Auto Sensing 50Hz | |||||||||||
Harmonic Distortion (THDv) | <1% (Linear load), <3% (Non Liner Load) | |||||||||||
Crest Factor | 3:1 | |||||||||||
Efficiency | Up to 94% Dual Conversion Mode, 99% ECO Mode | |||||||||||
BATTERY | ||||||||||||
DC Voltage | 120V/144V/180V | 180/192V | 220V | 360V | ||||||||
Charge Current | 10% of the Rated Battery AH | |||||||||||
Recharge Time | 8 Hours (90% of full capacity) | |||||||||||
SYSTEM FEATURES | ||||||||||||
LCD Indication | Input Voltage/Frequency, Output Voltage/Frequency | |||||||||||
LED Indication | Load Level, Battery Level, Line On, Battery On, Inverter On, By Pass, Fault & Reset Button | |||||||||||
Alarms / Protection | Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault. | |||||||||||
Overload Capability | <125% for 10 min, >125-150% for 1 min, >150% for 200 ms | |||||||||||
Transfer Time | AC to Battery : Oms, Inverter to Bypass : 4ms (Typical) | |||||||||||
ENVIRONMENTAL | ||||||||||||
Temperature | Operating: 0~40°C, Storage: -10°C ~ 55°C | |||||||||||
Humidity / Altitude | 0~95% RH Non-condersing / <1500 M | |||||||||||
Noise | Low Audible Noise Level | |||||||||||
PHYSICAL | ||||||||||||
Dimension WxDxH (mm) | 465x820x890 | 465x820x890 | 465x820x890 | |||||||||
Weight (Kg) | 90kg | 125kgs | 160kgs | 175kgs | ||||||||
STANDARDS | ||||||||||||
Quality | 1SO 9001, ISO 14001, OHSAS | |||||||||||
Safety | IEC/EN62040-1 | |||||||||||
EMC / Performance | |EC/EN62040-2; IEC/EN62040-3, Complying to CE | |||||||||||
COMMUNICATION INTERFACE | ||||||||||||
Standard | RS-232 Optional | |||||||||||
Optional | SNMP / ModBus / Dry Contact / USB / RS-485 | |||||||||||
Technology | Online Double conversion AC-DC-AC with high switching frequency VFI Inversion Technology IGBT Based Rectifier & Charger Section |